![]() | | Sign-in | Sign Up |  | | |
|
|
|
| Loudness Standards Guide |
VisLM supports current loudness metering standards (ITU-R BS.1770/1,
EBU R128, ATSC A/85) more...
Further information covering delivery requirements, LUFS, LKFS,
calibration and test tones here.
|
| |
| VisLM at InterBEE 2010 |
 |
VisLM
on demo at InterBEE 2010, both at the Media Integration Booth and with
a demonstration available after the EBU R128 Loudness Metering
panel.
|
| AES Loudness tutorial |
 |
NUGEN Audio metering in use by Matthieu Parmentier of France Télévisions, demonstrating the practicalities of Loudness measurement at the AES convention, London.
|
|
| |
 |
| Read
our step by step guide here. |
|
|
VisLM Loudness
Meter
|
Broadcast
| Film | Mastering | Multi-Media |
|
|
|
| VisLM-H |
VisLM
with history view (H) and data logging option |
 |
| VisLM-C |
VisLM
compact (C) |
 |
| |
| Measure
LKFS and LUFS |
ITU-R
BS. 1770/1 compliant
EBU R128 compliant
ATSC A/85 compliant
|
|
|
| NEW
in version 1.6 |
|
|
|
|
|
 |
|
 |
|
 |
| Automation Logging |
|
Resizable
interface
|
|
Dialog Gate |
|
|
|
|
|
 |
|
 |
|
 |
| AAX Native |
|
64-bit OSX Native |
|
Usability
enhancements |
True
cross-platform, multi-format loudness metering
|
The most fundamental question in audio production, how loud is it?
Simple and yet elusive, with loudness inconsistency and
incompatibilities present every day in broadcasts across the world.
With
detailed, objective loudness measurement, history and logging
facilities, VisLM provides a simple, ITU, ATSC and EBU standard
compliant*
way to measure, compare and
contrast loudness during production, broadcast and post production, on
the fly or for entire sections of audio.
VisLM introduces several essential parameters for audio measurement.
- True-Peak level metering
(inter-sample accurate level monitoring)
- Loudness Range (to help decide if
and how much dynamic compression to apply)
- Momentary 'instantaneous loudness'
for mixing by ear
- Short term loudness (3 second time
window)
- Program Loudness (long term
integrated loudness measurement)
|
*ITU-R
BS1770/1, ATSC A/85 and EBU R128 fully compliant 'EBU mode' and other
specific localisations more...
|
|
| |
| "I'm
impressed by the thoroughness with which Nugen Audio have designed
their loudness/metering plugin... Highly
recommended." |
| |
Bob Katz | 3x Grammy award-winning
Mastering Engineer
|
| |
|
 |
 |
Avid
Media Composer Compatibility: This version of VisLM is
compatible with MC 6.0 onwards, for
compatibility with prior releases of MC, please use VisLM v1.5.1
available here: Windows | Mac OSX
|
|
| |
| "Bright,
clean and easy to see exactly what’s going on. Using it I can really
see
how my mix is going to sound in the real world and with the presets I
know it’s going to be fine whatever the destination for my music!"
|
| |
Dan
Watts | Film & TV composer (HBO, BBC, ITV)
|
| |

|
| |
|
|
| |
"If
you are looking for a well designed, state of the art, highly efficient
and customisable loudness measurement plug-in and stand alone software
meter from a trusted name in loudness, then look no further - very
highly recommended indeed.'
|
Mike
Aiton | Audio Media Magazine
|
| |
| |
"VisLM
does everything required for effective loudness measurement and does it
well...
Cost effective; thoroughly researched" |
|
|
Rob
James | Resolution Magazine
(April 2011)
|
| |
Loudness metering |
Standardised, intuitive loudness compatibility
|
|
|
Standardized
loudness
metering represents the next generation of audio 'volume' control,
moving beyond the digital consideration of level and into
objective perceived loudness - Loudness is the sound level people
actually 'hear'. The NUGEN Audio VisLM loudness meter is a step closer
to the perfect loudness measurement tool: the human ear.
"Loudness
jumps and inconsistencies are the most common technical complaints
listeners and viewers of broadcast programs have... Switching to
loudness metering and normalization is a breakthrough in providing a
more consistent, and thus more pleasant, listening experience"
Florian Camerer | Sound Engineer, ORF TV | chairman EBU P/LOUD
|
| |
Maximum True Peak Level metering
|
|
|
The True Peak Level of an audio signal is the maximum value of the
signal, Sample Peak and QPPM (Quasi-Peak Program Meter) Meters do not
measure this level with accuracy as they miss the true peaks which
potentially lie between samples. The implementation of True Peak
metering to BS. 1770 allows these inter-sample peaks to be detected.
VisLM provides true peak metering for all audio channels from a single
mono source through to 5.1 surround production.
|
|
Practical
Applications - Loudness normalisation for the whole production
& broadcast chain
|
Loudness
normalization introduces a common reference point for all stages of
audio production, allowing audio professionals to remain in control of
audio quality and meet current & proposed legislation.
Post production
- Objectively measure constituent loudness
values
- Achieve average loudness harmonization
from differing sources
- Balance music/dialog/special effects
VisLM
simplifies the process of harmonizing dialog, music and sound effects
by allowing objective comparison of both loudness and loudness range (a
measure of the consistency of signal loudness), making the process of
loudness harmonization more rapid and reliable than ever before. As
well
as assisting in the balancing of different aspects of the soundscape,
VisLM can be used to quickly match recordings in different settings
(eg. documentary production, film soundtrack work) creating a more
consistent, harmonious listening experience.
Mixing | Mastering
- Take control of audio quality at source
- Avoid 'level shifting' further down the
broadcast stream
- Produce consistent masters
- Match average loudness across compilation
productions
- Preserve audio fidelity using True Peak
level meters
With
the introduction of recent legislation and the adoption of
new international standards loudness metering has become a
requirement for broadcasters the world over. To comply with
technical requirements, audio that does not meet target loudness
requirements will be 'level shifted' to maintain the channel average
loudness profile, which with current leveling practice will mean that
the audio is will probably be 'turned down'. To avoid this, loudness
control and normalization should be adopted.
Broadcast
| Transmission
- Harmonize program content
- Achieve loudness consistency within
channel
- Maintain loudness consistency across
channels
- Meet recent legislation and adopted
standards
- Manage live broadcast levels rapidly and
objectively
- Consistently balance
music/dialog/special effects
- Perform station monitoring and historical
diagnostic
Loudness
metering finally allows broadcasters to achieve consistent levels of
average loudness within and between channels. It is possible to measure
and harmonize the relative average levels of all types of program
material, be it music, live broadcast, dialog, advertising or effects
leading to a better listening experience and complying with recent
legislation (CALM Act etc.). VisLM is also
capable of providing detailed historical log files to allow station
postmortems (eg. checking the consistency of shared services, locally
inserted content etc.)
|
Clear
intuitive GUI
- Bar meter and clear numerical read-out
- 'Alert' warning options
- Loudness history (VisLM-H)
- Time position markers (VisLM-H)
- Loudness boundary indicators
EBU
R128 | ITU R BS 1770 | ATSC A/85 metering more...
- Momentary, Short term and Integrated
loudness
- Loudness range
- Overall program loudness measurement
- Maximum True Peak Level meters
- 'EBU Mode' meters
- Automatic mono through 5.1 compatibility
Data export (Vis LM-H only)
- Off-line data file export
- Multiple export parameters
- Post-mortem time logging
Stand
alone application for Win|OSX (VisLM-H only)
more...
VisLM-H | VisLM-C comparison Table here... |
| VisLM Loudness
Meter
|
Broadcast
| Film | Mastering | Multi-Media |
|
|
|
|
| VisLM-H |
VisLM
with history view (H) and data logging option |
 |
| VisLM-C |
VisLM
compact (C) |
 |
|
| |
|
| Save on VisLM |
 |
 |
Huge savings of up to 30% with our attractive product bundles. more...
|

|
 |
| System Requirements |
VisLM is available in RTAS, VST and AU formats for PC and Mac
(universal
binary)
Mac OSX 10.6.x, G5 1.4 GHz or
Intel® Core™ Duo 1.66 GHz, 512 MB RAM
Windows XP or Windows Vista, Pentium 1.4 GHz, 512 MB RAM
|
|
| NuGen Studio |
 |
 |
A complete solution for the
control and enhancement of your spatial image and our comprehensive
audio analysis software. more...
|
|
|
| Faster
than realtime loudness analysis directly within your Avid
Editor? |
 |
|
|
|